Central Analytical Laboratory

banner
Central Analytical Laboratory

Overview

The Central Analytical Laboratory (3155, FDIII) is well equipped with a number of sophisticated analytical instruments for the regular course works and research related activities. The following instrumental facilities as already established and available for services. 

  • FIELD EMISSION SCANNING ELECTRON MICROSCOPY (FE-SEM)



    FE-SEM is used to obtain topographical morphology and elemental information at magnifications of 10x to 300,000x, with virtually unlimited depth of field. The instrument has a high resolution of 1.5 to 2 nm.

    Make: FEI

    Model: Apreo LoVac

    Specifications:- NICol electron column, 110 x 110 mm eucentric stage, Multi-purpose holder, CCD IR camera, In-chamber Nav-Cam, In-lens detectors: Lower (T1) and Upper (T2), SE detector (ET-SED), Low-Vacuum SED (LVD)Aztec Standard EDS system inclusive of X-max 80 N SDD EDS detector SDD;Critical point dryer Q150T E S combined Sputtering & Carbon coater; PT-PCZ PC Controlled Ultra microtome; Glass Knife Maker

     

  • Gas Chromatography –Mass spectrometry (GC-MS/MS)




    Make: Shimadzu

    Model: GCMS-TQ8040 NCI

    Specifications:- Triple Quadrupole Gas Chromatograph –Mass Spectrometer with EI, PCI & NCI mode; DATABASE: 978-1-118-98089-7, NIST Mass Spectral Library 2014 for GCMS. AUTO INJECTOR & AUTO SAMPLER: Liquid Auto-Injector, AOC-20i, AOC-20S Liquid Autosampler with holding capacity of 150 Samples, AOC-20s Installation kit for TQMS, 1.5ml Sample Vial Set with white cap & septum, 100 pcs/set; FRONTIER LAB MULTISHOT PYROLYSER

  • NUCLEAR MAGNETIC RESONANCE (NMR) – 400 MHZ



    NMR spectrometer (400 MHz) equipped with an auto-sampler is a central facility of BITS Pilani at Pilani Campus. NMR is a powerful technique to elucidate the structure of organic molecules and inorganic complexes. A variety of NMR active nuclei such as 1H, 13C, 19F or 31P can be studies using the instrument.

    Make: Bruker

    Model: AVHD 400 AVANCE III HD 400MHz

    Specifications:- High performance actively shielded ASCENDTM 400MHz superconducting magnet system, 54 mm bore operation field at 9.4 Tesla strayfield: radial 0.5m / axial 1.0m, helium hold time >300 days helium level meter with alarm function for low helium level, nitrogen level sensor standard magnet stand with vibration damping accessory; SHIM SYSTEM/LOCK CHANNEL; AVANCE III HD ELECTRONICS; TRANSMITTER / DIGITAL RECEIVER DRU

  • HIGH COMPUTING COMPUTER CLUSTER





    Make: Hewlett Packard

    Specifications:- 256 Core, Master & Compute Nodes -Master / Head Node (DL60Gen9 / 2 x Intel Xeon E5-2630v3 (2.4GHz/8-core/20MB) / 96 GB ( 6 x HP 16GB 2Rx4 PC4-2133P-R Kit) / 1 x 6G 1TB SAS 7.2KRPM /HP Ethernet 10Gb 2P 560FLR-SFP+ Adptr/ RPS / iLO Scale Out/ 1 U Form Factor); - Compute Node (DL60Gen9 / 2 x Intel Xeon E5-2630v3 (2.4GHz/8-core/20MB) / 96 GB ( 6 x HP 16GB 2Rx4 PC4-2133P-R Kit) / 1 x 6G 1TB SAS 7.2KRPM /HP Ethernet 10Gb 2P 560FLR-SFP+ Adptr/ RPS / iLO Scale Out/ 1 U Form Factor); Compute Node with NVIDIA GPU (XL190 Gen9/ 2 x Intel Xeon E5-2630v3 (2.4GHz/8-core/20MB) / 96 GB ( 6 x HP 16GB 2Rx4 PC4-2133P-R Kit) / 1 X 6G 1TB SAS 7.2KRPM / HP Ethernet 10Gb 2P 560FLR-SFP+ Adptr/ 2 x NVIDIA Tesla K40C 12 GB Module / RPS /iLO Scale Out / 2U Form Factor)

  • Surface Enhanced Raman Spectrometer with Atomic force Microscopy (SERS-AFM)



    Make: HORIBA
    Model: Labram HR Evolution

    Specifications:-Lab RAM HR UV-VIS-NIR (200 - 2100 nm), -5X Visible Objective, 50X LWD Visible Objective -Full kit-XYZ for sample position, UV-VIS-NIR macro lens, Quartz Cell, Binoculars, MOD-3POS-KO (3 positions unit - 100% reflection, 100% transmission, 50% reflection), KIT-325-30-Hrev (325 nm laser kit) 40X NUV Objective 53011140 HR (2400 gm/mm holographic grating blazed at 330 nm), KIT-532-50-V-Hrev (532 nm laser kit), KIT-635-17-Hrev (He Ne laser kit 633 nm / 17 mW), KIT-785-100-Hrev (785 nm laser kit), TNS-SI (NIST traceable Si material)

     

  • Fully Spectral Confocal Laser Scanning Microscope




    Make: Carl Zeiss

    Model: LSM 880

    Specifications:- Fully Motorized and computer controlled inverted florescence research microscope with Axio observer 7 SP stage for LSM 880. Scanning stage 130 x 100 STEP set for LSM; halogen illuminator for transmitted light, carrier for transmitted light illumination for LSM, objectives, Real time online hardware based super resolution imagining [AIRYSCAN]

For Further Information Contact

Name : Central Analytical Laboratory
Co-ordinator : Dr. Paul Atish Tulshiram